Hastelloy C2000 is a nickel-chromium-molybdenum alloy developed by Haynes International as an advanced evolution of the widely used Hastelloy C276.

Introduced in the late 1990s, C2000 was specifically engineered to combine the superior resistance of C276 to reducing environments with dramatically improved resistance to oxidizing media, including ferric ions, cupric ions, and strong oxidants such as nitric acid and hydrochloric acid mixtures.
Hastelloy C2000 Chemical Composition
The nominal chemical composition of Hastelloy C2000 (as per ASTM B575, B564, B366, and B462) is presented below:
|
Element |
Weight % (Nominal) |
Typical Range (Actual) |
Purpose & Effect |
|
Nickel (Ni) |
Balance |
Remainder |
Primary matrix element; provides base corrosion resistance and ductility |
|
Chromium (Cr) |
23.0 |
22.0 – 24.0 |
Enhances resistance to oxidizing environments and localized corrosion (pitting/crevice) |
|
Molybdenum (Mo) |
16.0 |
15.0 – 17.0 |
Major contributor to resistance in reducing acids (HCl, H₂SO₄) and pitting resistance |
|
Copper (Cu) |
1.6 |
1.3 – 1.9 |
Unique addition that significantly improves resistance to sulfuric and hydrochloric acids, especially in oxidizing impurities |
|
Iron (Fe) |
≤3.0 |
≤2.0 typical |
Kept low to maintain corrosion performance |
|
Cobalt (Co) |
≤2.0 |
≤1.0 typical |
Limited to reduce risk of phase instability |
|
Manganese (Mn) |
≤0.50 |
≤0.30 typical |
Deoxidizer and machinability aid |
|
Silicon (Si) |
≤0.08 |
≤0.05 typical |
Strictly limited to prevent deleterious silicide formation |
|
Carbon (C) |
≤0.010 |
≤0.008 typical |
Ultra-low to avoid sensitization and intergranular corrosion |
|
Phosphorus (P) |
≤0.025 |
≤0.015 typical |
Controlled to minimize hot cracking and embrittlement |
|
Sulfur (S) |
≤0.010 |
≤0.005 typical |
Extremely low to enhance weldability and corrosion resistance |
|
Aluminum (Al) |
≤0.50 |
≤0.20 typical |
Limited; excess can form detrimental phases |
Hastelloy C2000 vs C276: Difference

Higher Chromium: Dramatically improves resistance to oxidizing species such as Fe³, Cu², and nitric acid.
Addition of Copper: A deliberate and patented addition that synergistically enhances performance in sulfuric acid and HCl-containing environments with oxidizing contaminants. This is the most distinguishing feature of C2000.
Higher Molybdenum: Maintains excellent resistance to reducing acids while supporting pitting and crevice corrosion resistance.
Ultra-low Carbon and Silicon: Ensures thermal stability and resistance to intergranular attack even after prolonged exposure in the 600–1000°C range.
Resulting Corrosion Performance
Virtually immune in hydrochloric acid up to 70 °C at all concentrations.
Excellent resistance in sulfuric acid up to 80 °C, even with oxidizing impurities.
Superior performance in wet chlorine, hypochlorite, and chlorine dioxide.
Outstanding resistance to pitting and crevice corrosion in seawater and brine.
ASME B16.9 Hastelloy C2000 Straight Tees And Crosses Dimension

|
Nominal Pipe Size(NPS) |
DN |
Outside Diameterat Bevel |
Center-to-End |
|
|
Run, C |
Outlet, M [Notes (1) and (2)] |
|||
|
1/2 |
15 |
21.3 |
25 |
25 |
|
3/4 |
20 |
26.7 |
29 |
29 |
|
1 |
25 |
33.4 |
38 |
38 |
|
1 1/4 |
32 |
42.2 |
48 |
48 |
|
1 1/2 |
40 |
48.3 |
57 |
57 |
|
2 |
50 |
60.3 |
64 |
64 |
|
2 1/2 |
65 |
73.0 |
76 |
76 |
|
3 |
80 |
88.9 |
86 |
86 |
|
3 1/2 |
90 |
101.6 |
95 |
95 |
|
4 |
100 |
114.3 |
105 |
105 |
|
5 |
125 |
141.3 |
124 |
124 |
|
6 |
150 |
168.3 |
143 |
143 |
|
8 |
200 |
219.1 |
178 |
178 |
|
10 |
250 |
273.0 |
216 |
216 |
|
12 |
300 |
323.8 |
254 |
254 |
|
14 |
350 |
355.6 |
279 |
279 |
|
16 |
400 |
406.4 |
305 |
305 |
|
18 |
450 |
457 |
343 |
343 |
|
20 |
500 |
508 |
381 |
381 |
|
22 |
550 |
559 |
419 |
419 |
|
24 |
600 |
610 |
432 |
432 |
|
26 |
650 |
660 |
495 |
495 |
|
28 |
700 |
711 |
521 |
521 |
|
30 |
750 |
762 |
559 |
559 |
|
32 |
800 |
813 |
597 |
597 |
|
34 |
850 |
864 |
635 |
635 |
|
36 |
900 |
914 |
673 |
673 |
|
38 |
950 |
965 |
711 |
711 |
|
40 |
1000 |
1016 |
749 |
749 |
|
42 |
1050 |
1067 |
762 |
711 |
|
44 |
1100 |
1118 |
813 |
762 |
|
46 |
1150 |
1168 |
851 |
800 |
|
48 |
1200 |
1219 |
889 |
838 |
GENERAL NOTE: All dimensions are in millimeters.
NOTES:
(1) Outlet dimension M for NPS 26 (DN 650) and larger is recommended but not required.
(2) Dimensions applicable to crosses NPS 24 (DN 600) and smaller.
ASME B16.9 Hastelloy C2000 Reducing Outlet Tees And Reducing Outlet Crosses Specification

|
Nominal Pipe Size (NPS) |
DN |
Outside Diameter at Bevel Run Outlet |
Center-to-End |
||
|
Run, C |
Outlet, M [Note (1)] |
||||
|
1/2 x 1/2 x 3/8 |
15 × 15 × 10 |
21.3 |
17.3 |
25 |
25 |
|
1/2 x1/2 x 1/4 |
15 × 15 × 8 |
21.3 |
13.7 |
25 |
25 |
|
3/4 x 3/4 x1/2 |
20 × 20 × 15 |
26.7 |
21.3 |
29 |
29 |
|
3/4 x 3/4 x 3/8 |
20 × 20 × 10 |
26.7 |
17.3 |
29 |
29 |
|
1 × 1 x 3/4 |
25 × 25 × 20 |
33.4 |
26.7 |
38 |
38 |
|
1 × 1 x 1/2 |
25 × 25 × 15 |
33.4 |
21.3 |
38 |
38 |
|
1 1/4 x 1 1/4 × 1 |
32 × 32 × 25 |
42.2 |
33.4 |
48 |
48 |
|
1 1/4 × 1 1/4 × 3/4 |
32 × 32 × 20 |
42.2 |
26.7 |
48 |
48 |
|
1 1/4 x 1 1/4 x 1/2 |
32 × 32 × 15 |
42.2 |
21.3 |
48 |
48 |
|
1 1/2 x 1 1/2 x 1/4 |
40 × 40 × 32 |
48.3 |
42.2 |
57 |
57 |
|
1 1/2 x 1 1/2 × 1 |
40 × 40 × 25 |
48.3 |
33.4 |
57 |
57 |
|
1 1/2 x 1 1/2 x 3/4 |
40 × 40 × 20 |
48.3 |
26.7 |
57 |
57 |
|
1 1/2 x 1 1/2x 1/2 |
40 × 40 × 15 |
48.3 |
21.3 |
57 |
57 |
|
2 × 2 × 1 1/2 |
50 × 50 × 40 |
60.3 |
48.3 |
64 |
60 |
|
2 × 2 × 1 1/4 |
50 × 50 × 32 |
60.3 |
42.2 |
64 |
57 |
|
2 × 2 × 1 |
50 × 50 × 25 |
60.3 |
33.4 |
64 |
51 |
|
2 × 2 × 3/4 |
50 × 50 × 20 |
60.3 |
26.7 |
64 |
44 |
|
2 1/2 x 2 1/2 × 2 |
65 × 65 × 50 |
73.0 |
60.3 |
76 |
70 |
|
2 1/2 x 2 1/2 x 1 1/2 |
65 × 65 × 40 |
73.0 |
48.3 |
76 |
67 |
|
2 1/2 × 2 1/2 × 1 1/4 |
65 × 65 × 32 |
73.0 |
42.2 |
76 |
64 |
|
2 1/2 × 2 1/2 × 1 |
65 × 65 × 25 |
73.0 |
33.4 |
76 |
57 |
|
3 × 3 × 2 1/2 |
80 × 80 × 65 |
88.9 |
73.0 |
86 |
83 |
|
3 × 3 × 2 |
80 × 80 × 50 |
88.9 |
60.3 |
86 |
76 |
|
3 × 3 × 1 1/2 |
80 × 80 × 40 |
88.9 |
48.3 |
86 |
73 |
|
3 × 3 × 1 1/4 |
80 × 80 × 32 |
88.9 |
42.2 |
86 |
70 |
|
3 1/2 x 3 1/2 × 3 |
90 × 90 × 80 |
101.6 |
88.9 |
95 |
92 |
|
3 1/2 × 3 1/2 × 2 1/2 |
90 × 90 × 65 |
101.6 |
73.0 |
95 |
89 |
|
3 1/2 × 3 1/2 × 2 |
90 × 90 × 50 |
101.6 |
60.3 |
95 |
83 |
|
3 1/2 × 3 1/2 × 1 1/2 |
90 × 90 × 40 |
101.6 |
48.3 |
95 |
79 |
|
4 × 4 × 3 1/2 |
100 × 100 × 90 |
114.3 |
101.6 |
105 |
102 |
|
4 × 4 × 3 |
100 × 100 × 80 |
114.3 |
88.9 |
105 |
98 |
|
4 × 4 × 2 1/2 |
100 × 100 × 65 |
113.3 |
73.0 |
105 |
95 |
|
4 × 4 × 2 |
100 × 100 × 50 |
114.3 |
60.3 |
105 |
89 |
|
4 × 4 × 1 1/2 |
100 × 100 × 40 |
114.3 |
48.3 |
105 |
86 |
|
5 × 5 × 4 |
125 × 125 × 100 |
141.3 |
114.3 |
125 |
117 |
|
5 × 5 × 3 1/2 |
125 × 125 × 90 |
141.3 |
101.6 |
124 |
114 |
|
5 × 5 × 3 |
125 × 125 × 80 |
141.3 |
88.9 |
124 |
111 |
|
5 × 5 × 2 1/2 |
125 × 125 × 65 |
141.3 |
73.0 |
124 |
108 |
|
5 × 5 × 2 |
125 × 125 × 50 |
141.3 |
60.3 |
124 |
105 |
GENERAL NOTE: All dimensions are in millimeters.
NOTE:
(1) Outlet dimension M for run sizes NPS 14 (DN 350) and larger is recommended but not required.