Monel 400 (UNS N04400, 67% nickel–31.5% copper–1.2% iron) is one of the few structural metals that can handle hydrofluoric acid (HF) across its full concentration range. But "can handle it" is not the same as "corrodes at zero rate."

This guide summarizes the published corrosion-rate data for Monel 400 in HF, shows exactly how concentration, temperature, and dissolved oxygen change that rate, and compares Monel 400 against Hastelloy C-276, Inconel 600, and 316 stainless steel so engineers can select the right material with numbers, not guesswork.
Does Monel 400 Resist Hydrofluoric Acid at All Concentrations and Temperatures?
Yes, but only under deaerated (oxygen-free), liquid-phase conditions. In that state, Monel 400 resists essentially every HF concentration - from dilute to over 90% - up to the boiling point, with a corrosion rate typically below 0.025 mm/year (about 1 mil per year, or "mpy").
Hydrofluoric acid is unusual: most acids get more aggressive as concentration rises, but HF's attack on Monel 400 depends far more on oxygen content and temperature than on concentration alone. Monel's copper content forms a thin, adherent fluoride film on the metal surface that blocks further attack, provided the acid is not aerated and not contaminated with oxidizing salts.
Once oxygen, air, or oxidizing metal ions (Fe3+, Cu2+) enter the system, that protective film breaks down and the corrosion rate can jump by one to two orders of magnitude. This single fact - oxygen exposure matters more than acid strength - is the most important idea in this entire article and is explained in detail in the sections below.
What Is the Measured Corrosion Rate of Monel 400 in Hydrofluoric Acid?
Independently published test data place Monel 400's corrosion rate in liquid HF between about 0.03 and 0.04 mm/year (1.2–1.6 mpy) near room temperature, rising to roughly 0.25–0.75 mm/year (10–30 mpy) in aerated, ambient-temperature 33 wt% HF, and climbing sharply above 90–120 °C.

The table below consolidates corrosion-rate measurements from peer-reviewed and national-laboratory sources. Rates are given in millimeters per year (mm/y) and mils per year (mpy, where 1 mpy = 0.0254 mm/y) so the data can be compared directly against ASTM/NACE corrosion-severity categories (generally: <0.1 mm/y = excellent/mild; 0.1–0.5 mm/y = acceptable for many services; >0.5 mm/y = generally unacceptable for long-term static equipment).
|
HF Concentration |
Temperature |
Condition |
Corrosion Rate (mm/y) |
Corrosion Rate (mpy) |
Source |
|
~4% (1 M) |
25 °C |
Liquid, laboratory electrochemical (Tafel) |
0.031 |
1.2 |
Stathopoulos et al., 2026 |
|
40% w/v |
25 °C |
Liquid, mass-loss |
0.04 |
1.6 |
Stathopoulos et al., 2026 |
|
33 wt% |
~23 °C (ambient, aerated) |
Liquid immersion, week 1 |
< 0.25 |
< 10 |
ORNL/TM-2002/165 |
|
33 wt% |
~23 °C (ambient, aerated) |
Liquid immersion, week 4 (rate still rising) |
≈ 0.74 |
≈ 29 |
ORNL/TM-2002/165 |
|
49% |
88–120 °C (threshold) |
Vapor, aerated or unaerated |
Rate begins rapid climb above this range |
Rate begins rapid climb above this range |
Kane et al., 1993 |
|
HF vapor (concentrated) |
200 °C (extrapolated) |
Vapor |
≈ 10× higher than Hastelloy C-276 at same conditions |
≈ 10× higher than Hastelloy C-276 at same conditions |
Rebak et al., 2001 |
Table 1. Corrosion rate of Monel 400 (alloy 400) in hydrofluoric acid as reported in laboratory and field studies. 1 mpy = 0.0254 mm/y.
The consistent pattern across every independent study is the same: dilute, deaerated, room-temperature HF produces corrosion rates so low they are considered negligible for engineering purposes, while aeration and elevated temperature can raise that rate by 10 to 30 times within the same concentration band.
How Does Temperature Affect Monel 400's Corrosion Rate in HF?
Temperature is the single strongest driver of corrosion. Rates stay low and stable up to roughly 90 °C, then increase sharply between about 90 °C and 120 °C, and continue climbing steeply beyond that - with or without oxygen present.
Laboratory work by Kane et al. (1993), later reproduced in the Oak Ridge National Laboratory (ORNL) study ORNL/TM-2002/165, tracked Monel 400's corrosion rate in 49% HF from ambient temperature up to about 150 °C. Below roughly 88 °C, the aerated and unaerated corrosion rates remain relatively close together and low.
Once temperature crosses the 88–120 °C band, the corrosion rate accelerates rapidly in both aerated and unaerated conditions - a rare case where oxygen exclusion alone can no longer control corrosion. At the elevated transfer temperatures typical of industrial HF processing (around 200 °C), field and literature data reviewed by Rebak et al. (2001) show Monel 400's vapor-phase corrosion rate reaching roughly ten times that of Hastelloy C-276 under the same conditions.
For plant designers, the practical takeaway is a temperature threshold, not a single number: below about 90 °C, well-deaerated Monel 400 equipment can be expected to give a long, predictable service life; above about 120 °C, corrosion allowance calculations should assume a sharply higher rate, and alternative alloys should be evaluated for continuous high-temperature duty.
Does HF Concentration or Temperature Have the Bigger Effect on Corrosion?
Temperature and aeration (dissolved oxygen) dominate; concentration is a secondary variable across most of the practical 0–70% HF range, though very high concentrations combined with high temperature compound the effect.

This surprises many engineers used to acids like sulfuric or nitric, where concentration is usually the primary corrosion driver. For Monel 400 in HF, published concentration-scan data (for example, the classic Nickel Institute immersion tests across 0.05%, 1%, 10%, 24%, and 48% HF at 24 °C, 50 °C, and 76 °C) show the corrosion rate shifting far more between temperature steps than between concentration steps at a fixed temperature. The Stathopoulos et al. (2026) electrochemical data reinforce this: moving from about 4% HF to 40% HF at the same 25 °C only changed the corrosion rate from 0.031 to 0.04 mm/y - a small increase compared with the 10–30× jump caused by aeration or a 90 °C+ temperature rise.
This does not mean concentration is irrelevant. At a given elevated temperature, higher HF concentration still increases both the corrosion rate and the risk of stress corrosion cracking, and very high concentrations (>85–90% HF) reduce the water activity in ways that can change which corrosion mechanism dominates. The practical design rule is to control temperature and oxygen first, then verify concentration-specific margins for the actual process stream.
Why Does Aeration (Dissolved Oxygen) Multiply the Corrosion Rate?
Oxygen and oxidizing contaminants (O2, Fe3+, Cu2+, or mixed acids such as HF-HCl) strip away Monel 400's protective fluoride film and drive continuous anodic dissolution, which can raise the corrosion rate by 10–100× compared with deaerated liquid HF.
In oxygen-free HF, Monel 400's nickel-copper surface forms a thin, adherent, largely insoluble fluoride layer that acts as a passive barrier, similar in function (though not composition) to the chromium-oxide film that protects stainless steels. Oxygen and oxidizing ions destabilize this film through continual oxidation-reduction cycling at the metal surface, exposing fresh metal to renewed attack. The 2026 Stathopoulos et al. study measured this synergy directly: 1 M HF alone gave a corrosion rate of 0.031 mm/y, and 1 M HCl alone gave 0.018 mm/y, but the combined 1 M HF + 1 M HCl mixture produced 0.051 mm/y - higher than the sum of the two acids tested separately, confirming a synergistic (not merely additive) corrosive mechanism when contaminants are present.
The same study found that vapor-phase exposure is consistently worse than liquid-phase exposure at the same nominal concentration and temperature, because moisture condensing on metal surfaces in the vapor space is continually replenished with fresh oxygen from the surrounding gas, while liquid-phase acid in a closed vessel more easily stays oxygen-depleted. This is why HF plant designers specify inert-gas (nitrogen) blanketing and dry, oxygen-free process conditions as the primary corrosion-control strategy for Monel 400 equipment, rather than relying on concentration limits alone.
Can Monel 400 Suffer Stress Corrosion Cracking (SCC) in HF Service?
Yes. Under moist, aerated, dilute HF vapor (up to about 0.5% HF) at temperatures up to roughly 95 °C, Monel 400 can develop transgranular stress corrosion cracking, with cracks reported in as few as 4–15 days in laboratory testing.
This is a distinct failure mode from general mass-loss corrosion and is documented in the ASM Handbook, Volume 13 (Corrosion), citing laboratory work by Ciaraldi, Berry, and Johnson (1982). The mechanism, described in earlier work by Copson and Cheng, involves the buildup of cupric fluoride deposits on the metal surface in moist, oxidizing HF vapor; these deposits create local conditions that promote cracking even though the general corrosion rate in the same environment may look moderate. Notably, K-Monel (UNS N05500), a higher-strength, precipitation-hardened variant, is only marginally more resistant to this cracking than standard Monel 400 - the overlap between the two alloys' cracking behavior is wide enough that alloy selection alone should not be relied on to prevent SCC.
The practical control measure, repeated across every source reviewed for this article, is the same one used to control general corrosion: exclude oxygen from the vapor space. Refinery HF alkylation units, for example, are routinely maintained under conditions that minimize air ingress specifically because both general corrosion and SCC of Monel 400 depend heavily on oxygen availability.
How Does Monel 400 Compare to Hastelloy C-276, Inconel 600, and 316 Stainless Steel in HF?
In deaerated liquid HF at moderate temperature, Monel 400 is a cost-effective, well-proven choice. At high temperature, in aerated/oxidizing HF, or where the longest possible service life is required, Hastelloy C-276 outperforms Monel 400 by a wide margin. 316 stainless steel is unsuitable for liquid-phase HF service at any of the concentrations and temperatures reviewed here.
|
Alloy |
Nominal Composition |
Behavior in HF (per reviewed sources) |
Relative Ranking |
|
Monel 400 (N04400) |
67% Ni – 31.5% Cu – 1.2% Fe |
Excellent in deaerated liquid HF at all concentrations to boiling; corrosion accelerates sharply above ~90–120 °C or with aeration; susceptible to SCC in moist, aerated, dilute vapor |
Strong general-purpose choice; watch temperature and oxygen |
|
Hastelloy C-276 |
57% Ni – 16% Cr – 16% Mo – 4% W |
Outperformed Monel 400 and Inconel 600 in every comparative test reviewed, especially at high temperature and under oxidizing/aerated conditions (~10× lower rate than alloy 400 at 200 °C in vapor) |
Best performer for severe or high-temperature HF service |
|
Inconel 600 |
76% Ni – 15.5% Cr – 8% Fe |
Moderate resistance; attack concentrates at the liquid/vapor interface; roughly 4× better than 316 SS in immersion but well behind Hastelloy C-276 and Monel 400 in most direct comparisons |
Intermediate; used mainly for bellows/vapor-exposed parts |
|
316 Stainless Steel |
12% Ni – 17% Cr – 2.5% Mo – balance Fe |
Severe, rapid attack below the liquid line; corrosion rates measured at 550–1,800 mpy (14–46 mm/y) in 33 wt% HF immersion testing |
Not suitable for liquid HF contact |
Table 2. Comparative HF corrosion performance of common high-alloy materials, based on ORNL/TM-2002/165, Rebak et al. (2001), and related literature.
A useful way to remember the ranking for demanding, high-temperature, or oxidizing HF service is: Hastelloy C-276 > Inconel 600 > Monel 400 > 316 stainless steel. For mild, deaerated, moderate-temperature liquid HF - the majority of storage, transfer, and low-temperature process applications - Monel 400 remains the industry-standard, cost-effective material of construction.
What Are the Practical Temperature and Concentration Limits for Monel 400 in HF Service?
Monel 400 is well suited to essentially any HF concentration in deaerated liquid service up to the boiling point; caution is warranted above roughly 90 °C, in moist aerated vapor, or wherever oxidizing contaminants are present, and Hastelloy C-276 should be considered above roughly 120 °C or under continuous oxidizing conditions.

|
Service Condition |
Guidance |
|
Deaerated liquid HF, any concentration, up to boiling point |
Monel 400 is well suited; expect corrosion rates on the order of 0.025 mm/y (1 mpy) or lower over long-term service. |
|
Aerated liquid or moist vapor, below ~90 °C |
Usable with caution; corrosion rate can rise to the 0.25–0.75 mm/y (10–30 mpy) range, and SCC risk exists in dilute (≤0.5%) vapor - minimize oxygen ingress and moisture cycling. |
|
Any HF phase, 90–120 °C |
Transition zone; corrosion rate begins a steep, temperature-driven climb even without aeration. Reassess corrosion allowance and inspection frequency. |
|
Continuous service above ~120 °C, or with sustained O2/Fe3+/Cu2+ exposure |
Corrosion rate accelerates sharply; evaluate Hastelloy C-276 or an equivalent Ni-Cr-Mo alloy for continuous-duty components. |
|
Mixed-acid streams (e.g., HF + HCl condensates) |
Expect synergistic acceleration beyond either acid alone; design for the mixed-acid corrosion rate, not the HF rate in isolation. |
Table 3. Engineering guidance for Monel 400 selection in HF service, derived from the corrosion data reviewed in this article. These figures summarize published test data and are not a substitute for project-specific corrosion testing.
Frequently Asked Questions
What is Monel 400's corrosion rate in hydrofluoric acid?
In deaerated liquid HF at moderate temperature, Monel 400 typically corrodes at less than 0.025–0.04 mm/year (roughly 1–1.6 mpy). In aerated 33 wt% HF at ambient temperature, published test data show the rate rising to about 0.25–0.74 mm/year (10–29 mpy) over a one-month exposure.
Can Monel 400 be used in 49% hydrofluoric acid?
Yes. Monel 400 is widely used in 49% HF liquid service, including HF alkylation units, provided the system is kept deaerated and operating temperatures stay below roughly 90–120 °C. Above that range, corrosion accelerates sharply regardless of oxygen content.
Is Monel 400 resistant to hydrofluoric acid stress corrosion cracking?
Not completely. Monel 400 can develop transgranular stress corrosion cracking in moist, aerated, dilute HF vapor (up to about 0.5% HF) at temperatures up to roughly 95 °C, with cracking reported in laboratory tests within 4–15 days. Excluding oxygen from the vapor space is the primary control measure.
Does increasing HF concentration always increase Monel 400's corrosion rate?
Only modestly on its own. Across most of the practical concentration range, temperature and dissolved oxygen change the corrosion rate far more than concentration does. Concentration becomes more significant only when combined with elevated temperature or oxidizing contaminants.
Which alloy should replace Monel 400 for high-temperature HF service?
Hastelloy C-276 is the standard upgrade. Literature data show it corroding at roughly one-tenth the rate of Monel 400 in HF vapor at 200 °C and consistently outperforming Monel 400 under aerated or oxidizing conditions at any temperature.