Quick Answer Review nozzle corrosion and weld geometry in one meeting, not two. A Hastelloy nozzle rarely fails because the alloy is wrong. It fails where geometry creates a local environment worse than the bulk liquid (a crevice, a stagnant pocket, an unfused root, a rough bead) and where weld metal is slightly less corrosion resistant than wrought metal. In Haynes G48 testing, C-276 starts crevice attack at 55 °C but pitting only above 140 °C.
Use one combined register. For every weld and wetted feature, record the geometry, the local conditions, the weld procedure evidence (interpass 93 °C max, clean joint, convex first bead, no unfused root), the inspection result, and the test or coupon that confirms it. Then accept, change, or monitor.
|

A reactor nozzle looks simple: a pipe welded into a shell with a flange on the end. It is actually one of the most demanding spots on the vessel. It joins two different thicknesses, creates welds that must be made from awkward positions, adds a gasket face, and often traps liquid or vapor. Corrosion teams and welding teams often review it separately. The corrosion team looks at chemistry and temperature. The welding team looks at procedures and inspection. Problems fall between the two.
Why must local corrosion and weld geometry be reviewed together at a nozzle?
Because a nozzle's local corrosion risk is created by its geometry and welds, not only by the process liquid. A review that checks chemistry alone, or welding alone, cannot see the whole risk.
Haynes states that the choice of weld joint design is critical and that poor joint design can negate even the most optimum welding conditions. Haynes also reports that weld metal generally corrodes faster than wrought metal in some acids. Those two facts together mean that a geometry problem and a corrosion problem can be the same problem.
Crevices are the clearest example. The ASTM G48 test finds the lowest temperature at which pitting (CPT) or crevice attack (CCT) starts in acidified ferric chloride. For every alloy below, the crevice temperature is far lower than the pitting temperature. A crevice is the easier place for corrosion to start.
Table 1. Crevice temperature is much lower than pitting temperature (ASTM G48, acidified 6% FeCl3)
|
Alloy |
Critical pitting temp. (CPT) |
Critical crevice temp. (CCT) |
Gap between them |
|
316L |
15 °C |
0 °C |
15 °C |
|
254SMO |
60 °C |
30 °C |
30 °C |
|
Alloy 625 |
100 °C |
40 °C |
60 °C |
|
C-276 |
Above 140 °C |
55 °C |
More than 85 °C |
|
C-22 |
Above 140 °C |
80 °C |
More than 60 °C |
|
C-2000 |
Above 140 °C |
80 °C |
More than 60 °C |
What this means for a nozzle. If a feature creates a crevice (a gasket face, an unfused root, a deposit under a lip), the safe temperature of the alloy there is closer to the CCT than to the CPT. That is why geometry has to be on the corrosion agenda.
Which nozzle weld and geometry features create local corrosion risk?
Seven features cause most of the review findings: unfused or partial-penetration roots, oxidized ("sugared") roots, concave beads, trapped oxides between passes, gasket faces, stagnant pockets, and liquid-vapor lines.
Nickel-alloy weld metal is "sluggish." It does not flow and wet the joint sidewalls as readily as steel, and weld penetration is shallow. Haynes says this promotes incomplete fusion, and that raising the current does not fix the shallow penetration. Table 2 links each feature to its local risk and to what to look for.
Table 2. Nozzle features and the local corrosion risk each one creates
|
Feature |
Local risk |
What to look for |
Evidence level |
|
Unfused or partial-penetration root |
Open gap becomes a crevice facing the process |
Root-side examination; weld detail on drawing; volumetric test |
Haynes (defects); practitioner views on full penetration (informal) |
|
Oxidized ("sugared") root |
Rough, porous root surface that traps liquid and corrodes |
Root appearance; purge records; radiographic quality |
Haynes bulletin on back purging (reproduction) |
|
Concave or narrow bead |
Weld surface in tension; solidification cracking |
Bead contour; joint angle and root gap |
Haynes (weld joint design) |
|
Oxide trapped between passes |
Inclusions and incomplete fusion |
Cleaning records; sectioned qualification welds |
Haynes (joint preparation) |
|
Gasket face and flange crevice |
Crevice attack governed by CCT, not CPT |
Face finish; gasket type; deposit buildup |
Haynes G48 data (Table 1) |
|
Stagnant pocket or dead leg |
Liquid sits, concentrates, or dries between batches |
Orientation; drain path; rinse and dry practice |
EETA engineering guidance |
|
Liquid-vapor line |
Accelerated attack in the transition zone |
Where the nozzle meets the liquid level; condensing zones |
ASTM G4 (transition zones) |
A note on full-penetration nozzle welds
ASME Section VIII Division 1 shows many acceptable nozzle attachment details in Fig. UW-16.1, and practitioners note that full penetration is not mandated for every nozzle. Some practitioners treat full penetration as the default in corrosive service because a sealed partial-penetration gap can trap process liquid, while others see little risk when the gap is sealed by a fillet. These are informal views, not code requirements. The safe approach is to decide on the weld detail for each nozzle, state it on the drawing, and review it with the corrosion team.
How does weld metal compare with wrought metal for local corrosion?
Weld metal is usually somewhat less corrosion resistant than wrought metal, though not in every acid. Overalloyed filler metals narrow the gap in some cases, but in Haynes' severe-solution test the base metal had the larger effect.

Weld metal is a cast structure with chemical segregation, so it is less uniform than wrought metal. Haynes tested all-weld-metal samples against wrought base metal for C-276 and C-2000. Results varied by acid.
Table 3. Weld metal against wrought base metal (Haynes data, mpy)
|
Alloy and environment |
Weld metal |
Wrought base metal |
Comment |
|
C-276, 70% H2SO4, 66 °C |
5.1 |
2.0 |
Weld about 2.5 times higher |
|
C-2000, 70% H2SO4, 66 °C |
2.4 |
0.2 |
Weld about 12 times higher |
|
C-2000, 90% H2SO4, 66 °C |
2.9 |
0.6 |
Weld about 5 times higher |
|
C-2000, 10% HCl, 38 °C |
2.1 |
<0.1 |
Weld clearly higher |
|
C-2000, 15% HCl, 38 °C |
2.4 |
7.0 |
Weld lower than wrought |
|
C-2000, 20% HCl, 38 °C |
8.0 |
6.3 |
Close |
Haynes also tested base metal and filler combinations in a deliberately severe solution (3 M NaCl + 0.1 M FeCl3 + 0.1 M NaF, pH 1, 75 °C, 39 days), developed for a waste-incineration scrubber.
Table 4. Base metal and filler combinations in a severe chloride-fluoride solution
|
Base metal / filler |
Corrosion rate (mpy) |
What it shows |
|
C-22 / C-22 |
0.17 |
Best result of the set |
|
C-276 / C-276 |
1.14 |
Matching filler |
|
C-276 / C-22 |
1.02 |
Overalloyed filler gave only a modest gain |
|
Alloy 625 / Alloy 625 |
100 |
Base metal limits the result |
|
Alloy 625 / C-22 |
94 |
Better filler cannot rescue a weaker base metal |
|
AL-6XN / Alloy 625 |
112 |
Dissimilar joint |
|
AL-6XN / C-22 |
72 |
Filler helped, base metal still limiting |
|
316 stainless / 316 stainless |
203 |
Reference |
Source: Haynes International, "Performance in Hazardous Waste Treatment Applications" (Los Alamos National Laboratory test). Severe laboratory conditions; Haynes reports that C-22 base metal and filler were selected for the scrubber system after these tests.
Haynes notes that C-22 and C-2000 are used extensively as overalloyed fillers. The data say to choose the filler for your envelope, qualify it in a procedure, and not assume that an overalloyed filler cures every weld-metal problem. The base metal and the weld quality still matter most.
What welding controls protect corrosion resistance at a nozzle?
Control heat input and interpass temperature (93 °C maximum), keep the joint clean, remove oxide between passes, use a joint design with a wide root and convex first bead, protect the root, and avoid post-weld heat treatment in the sensitive range.
Table 5. Haynes welding guidance and why it matters for local corrosion
|
Control |
Haynes guidance |
Why it matters locally |
|
Preheat |
Generally not required; ambient is sufficient |
Avoids unnecessary heat exposure |
|
Interpass temperature |
Maximum 200 °F (93 °C); water quench or rapid air cooling acceptable |
Limits total heat input and time at temperature |
|
Heat input |
Stringer beads; avoid slow travel, especially on thin parts |
Reduces heat-affected-zone damage |
|
Post-weld heat treatment |
Normally as-welded; avoid 1000 – 1500 °F; only full solution anneal is acceptable; no 1200 °F stress relief for C-276 |
A wrong heat treatment can harm corrosion resistance |
|
Cleanliness |
Free of oxides, scale and carbon; lead, sulfur and phosphorus cause severe embrittlement or cracking |
Contamination makes weld metal and HAZ weak spots |
|
Interpass oxide |
Remove between passes (stainless brush, light grinding) |
Trapped oxide causes inclusions and incomplete fusion |
|
Root protection |
Back-purge; if impossible, grind the root and weld both sides |
Avoids "sugar" roots that trap liquid |
|
GMAW mode |
Pulsed spray strongly encouraged; short-circuiting can give cold lap |
Fewer incomplete-fusion flaws |
|
Starts and stops |
Grind starts and stops (all arc processes) |
Removes crater defects |
Sources: Haynes International "Temperature Control and Heat Treatment of Weldments," "Weld Joint Preparation," GMAW and Welding Defects pages; Haynes C-276 welding parameters page; Haynes back-purging bulletin (reproduction): back purge about 40 CFH and torch gas about 10 CFH in that bulletin's suggested parameters.
Joint geometry for nickel alloys is different
Haynes says nickel-alloy joints typically need a larger included angle, a wider root opening, and a reduced land than carbon or stainless steel joints. A joint that is too narrow produces a concave bead, which puts the weld surface in tension and promotes solidification cracking. The first bead should be convex. Haynes' typical butt joints are shown below; nozzle groove welds follow the same principles but use their own details.
Table 6. Haynes typical single-V butt joints for manual welding
|
Material thickness |
Root opening |
Land thickness |
Included angle |
|
6.3 mm (1/4 in) |
1.6 – 3.2 mm |
0.8 – 2.4 mm |
60 – 75° |
|
12.7 mm (1/2 in) |
0.8 – 4.0 mm |
0.8 – 2.4 mm |
60 – 75° |
|
19.1 mm (3/4 in) |
0.8 – 4.0 mm |
0.8 – 2.4 mm |
60 – 75° |
Source: Haynes International, Weld Joint Design page, Figure 1 (butt joints; joint type II). Nozzle-to-shell welds are not covered by this figure; follow the qualified procedure and drawing.
How should you inspect nozzle welds for geometry and surface condition?
Inspect geometry and surface first, then volume. Look at bead contour, root condition, oxide and heat tint, and then confirm soundness with penetrant and volumetric testing as the specification requires.
Table 7. Inspection methods and what each shows at a nozzle
|
Method |
What it shows |
Notes for nickel alloys |
|
Visual (with gauge) |
Bead contour, undercut, spatter, heat tint, root appearance |
Convex first bead expected (Haynes); record contour |
|
Liquid penetrant (PT) |
Surface-breaking cracks and fusion flaws |
Coarse grinding scratches can trap penetrant and make PT harder or invalid (Haynes) |
|
Radiographic (RT) or ultrasonic (UT) |
Internal flaws, lack of fusion, incomplete penetration |
Poor root protection makes radiographic acceptance very difficult (Haynes bulletin) |
|
PMI |
Base metal and filler identity |
Confirm filler heat and chemistry on the weld, not only on the wire spool |
|
Wall thickness mapping (UT) |
Local thinning at the neck and weld |
EETA practice for baselining before service |
Remove oxide and contaminants after welding. Haynes advises that its alloys are generally inert to cold acid pickling and that effective descaling uses a molten-salt bath followed by hot acid pickling. For welded parts, confirm the cleaning procedure with the fabricator and the owner so that it does not leave iron or acid residues in crevices.
Which tests and monitoring confirm local corrosion performance?
Use ASTM G48 on qualification coupons that include weld metal and heat-affected zone, and field coupons per ASTM G4 in the real vessel. Use plain coupons for rates and welded coupons for comparing weld, HAZ, and base metal.

Haynes states that plain samples are better for determining corrosion rates, while welded samples help compare base metal, weld metal, and heat-affected zone behavior. ASTM G4 adds limits: coupon tests are designed mainly for general corrosion, cracking may show no mass loss, velocity effects may not reproduce, and small coupons may not cover liquid-to-vapor transition zones.
Table 8. Tests for confirming local corrosion performance
|
Test or tool |
What it reveals |
Limitation |
|
ASTM G48 (ferric chloride) |
CPT and CCT: the temperature at which pitting or crevice attack starts |
Not the same as your fluid; a screening test |
|
Laboratory immersion (ASTM G31) |
Corrosion rate of base, weld and HAZ coupons in your liquid |
Lab conditions; no velocity or deposits |
|
Plant coupons (ASTM G4) |
Real-process rate and local attack |
Placement must match aeration and location; a single exposure is a snapshot |
|
Welded field samples |
Weld versus HAZ versus base metal in service |
Compare to plain coupons for rates |
|
Thickness mapping (UT) |
Local wall loss at the nozzle over time |
Needs a baseline and repeat locations |
Sources: Haynes HYBRID-BC1 datasheet (field test program, G48 table); ASTM G4 (iTeh previews); ASTM G31-72 reproduction; EETA summary.
How do you run a combined corrosion and weld-geometry review?
Draw the nozzle, mark every weld and wetted feature, record the local conditions at each, check each against the weld procedure and inspection evidence, and then decide whether to accept, change, or monitor it.
- Collect the process envelope. Chemicals, concentrations, temperatures, upsets, cleaning agents, and contaminants such as chlorides and oxidizers.
- Draw the nozzle. Label every weld, crevice, gasket face, dead leg, internal projection, and liquid-vapor line.
- Mark local conditions. Note where liquid stagnates, where vapor condenses, where deposits form, and where temperature differs from the bulk.
- Check the weld record. Compare the WPS and weld log with Table 5: interpass temperature, heat input, cleaning, root protection, and filler.
- Check the inspection record. Compare visual, PT, RT or UT, and PMI results with Table 7.
- Check the test evidence. Review G48 coupons, field coupons, and thickness readings (Table 8).
- Decide and record. Accept, modify the detail, add monitoring, or restrict the process list.
Table 9. Example combined review register (illustrative rows)
|
Location |
Geometry feature |
Local condition |
Weld and inspection evidence |
Action |
|
Charge nozzle, shell weld |
Set-in groove weld, partial penetration with fillet |
Chloride-bearing acid; occasional deposits |
Root not examined; PT only |
Add volumetric test; discuss detail change |
|
Charge nozzle, neck |
Dip pipe projects inside |
Liquid-vapor line at the weld |
Interpass ≤93 °C; PT clear |
Add coupon at the liquid level; thickness baseline |
|
Outlet nozzle, flange face |
Raised-face gasket seat |
Crevice under gasket; hot batch |
Machined face; no weld nearby |
Check CCT margin for the alloy; inspect face each outage |
|
Vent nozzle |
Upward-facing stub, no drain |
Condensate may collect between batches |
Weld records complete |
Review orientation; add rinse and dry step |
What should a buyer or fabricator specify for Hastelloy reactor nozzles?
Specify the alloy and forms, the nozzle weld detail, the filler and procedure limits, cleanliness and root protection, the inspection plan, and the documents to be supplied. A short written specification stops most disputes about local corrosion after startup.

- Alloy and forms: the C-type alloy grade; forgings to ASTM B564, plate to B575, pipe to B622 or B619/B626, as applicable.
- Weld detail: state full or partial penetration on the drawing; do not leave it to the fabricator.
- Filler: matching or overalloyed, with the reason; qualified procedure and PQR.
- Welding limits: no preheat; interpass 93 °C maximum; stringer beads; pulsed spray for GMAW; root back-purge or grind-and-weld-both-sides.
- Cleanliness: joint free of oxides, carbon, lead, sulfur and phosphorus; oxide removed between passes.
- Post-weld treatment: as-welded, or full solution anneal only; no stress relief at 1000 to 1500 °F.
- Inspection: visual with contour record, PT with a surface finish suited to it, RT or UT, PMI of filler and weld.
- Test evidence: G48 on qualification coupons with weld and HAZ where required; plan for field coupons.
- Documents: EN 10204 3.1 certificate, WPS/PQR, weld map with welder IDs, inspection reports.
JN Alloys supplies Hastelloy among its nickel alloys and lists customized processing according to drawings, welding of pipeline products, and technical consultation among its services. Its production equipment includes automatic welding, on-line solution annealing, heat treatment, and pickling for pipe production. Its testing equipment includes X-ray testing (real-time radiographic and film), a spectrum analyzer, PMI testing, a universal tensile tester, a metallographic analyzer, and an impact tester. Fabrication scope for reactor nozzles should be confirmed with JN for each project.
Frequently Asked Questions
Q: Why do reactor nozzles often show local corrosion before the rest of the vessel?
A: A nozzle combines features that can make the local environment worse than the bulk liquid: crevices at gasket faces, stagnant pockets, vapor-liquid lines, and welds. In Haynes G48 testing, C-276 starts crevice attack at 55 °C but pitting only above 140 °C, which shows how much easier it is for a crevice to start than a pit. The exact failure point still has to be confirmed in each case.
Q: Is a full-penetration nozzle weld required for Hastelloy?
A: ASME Section VIII Div. 1 shows many acceptable nozzle weld details in Fig. UW-16.1, and full penetration is not mandated for every nozzle. Practitioners commonly specify full penetration for corrosive service because a partial-penetration root can leave an unfused gap open to the process. Whether to require it is the purchaser's decision, so write it into the purchase order and drawing.
Q: What is the maximum interpass temperature when welding Hastelloy?
A: Haynes suggests a maximum interpass temperature of 200 °F (93 °C). Preheating is generally not required, and water quenching or rapid air cooling may be used to control interpass temperature.
Q: Does a Hastelloy nozzle weld need post-weld heat treatment?
A: Usually not. Haynes says corrosion-resistant alloys are used as-welded in the vast majority of services. It advises avoiding heat treatment in the 1000 to 1500 °F (538 to 816 °C) range, says a full solution anneal is the only acceptable post-weld heat treatment for these alloys, and says stress relief near 1200 °F (650 °C) is not recommended for C-276.
Q: Should I use matching filler or an overalloyed filler?
A: Haynes notes that C-22 and C-2000 alloys are used extensively as overalloyed filler metals. In a Haynes severe-solution test, however, C-22 filler on C-276 base metal gave 1.02 mpy against 1.14 mpy with matching C-276 filler. The gain was modest because the base metal dominated that test. Choose the filler from your own envelope and a qualified procedure.
Q: Why does grinding grit matter on weld preparations?
A: Haynes says a joint surface should be free of oxides, scale, carbon, and other contaminants. Coarser abrasives remove them faster but leave scratches that can hide fine cracks and trap penetrant, making dye-penetrant inspection harder or invalid. Progressively finer grits give a finish that is easier to inspect.
Q: Do laboratory corrosion results apply directly to a nozzle?
A: They are a guide. Haynes tests are run in reagent-grade solutions, and Haynes encourages field trials. ASTM G4 notes that coupon tests may not reproduce high-velocity effects and may not cover liquid-to-vapor transition zones. Welded coupons help compare base metal, weld metal, and heat-affected zone.
Q: Which Hastelloy product forms are used for nozzles?
A: Haynes lists forgings under ASTM B564, plate under B575, rod and bar under B574, seamless pipe under B622, welded pipe under B619 and B626, and fittings under B366 and B462 for the C-type alloys. Confirm the form, heat, and filler on the certificate and weld records.